Marine
Marine logo

Marine solution: Plug and play electrical installation on board

 
 

Value proposition

Main drivers:
  • Reliable operation ensuring safety of people transported
  • Reduced volume, weight and installation time while improving performance
  • No maintenance for perfect service continuity
  • Easy upgrading and extension of the installation

 

Solution in brief:
From centralised to decentralised electrical distribution
, allowing optimisation of main switchboard size by supplying:

  • All decks with  Canalis KS risers
  • All cabins with Canalis KN installed in the suspended ceilings
  • Lighting with KDP installed in the suspended ceilings

 

Value propositions:

  • Safe and reliable operation from a prefabricated and factory-tested system: a manufacturer's guarantee avoiding all installation defects
  •  A compliant offer with IEC 60439 - 2, certified by third party labs, and type - approved by major classification societies: BV, GL, DNV, ABS
  • Volume, weight and installation time reduced by 2 while improving performances

 - compact size ensuring space saving with respect to cables
 - with aluminium conductors lighter than copper

 - prefabricated design with plug-in components ensuring simpler and quicker installation without need of specific skills and tools.


Differentiation factors:

  • Safety: Halogen-free product, reduced calorific value, a fire barrier solution tested between all decks, RoHS-compliant
  • Flexibility: Possible addition of future loads with power on, ease of cabin adaptation according to customers' varying needs, ease of upgrading of lighting circuits in event of change of room use
  • Maintenance free: Canalis enhances installation legibility and maintainability, all electrical contacts are made of elastic and require no maintenance

 

 

Architecture

Architecture
 

Main characteristics

Prefabricated busbar trunking systems:


- Canalis KS: Rigid busbar trunking

  • Nominal current 100 to 1000A
  • 4 live conductors
  • Tap-off points (for connectors and units 25 to 400A) every meter on each side
  • Degree of protection IP55


- Canalis KN: Rigid busbar trunking

  • Nominal current 40 to 160A
  • 4 live conductors
  • Tap-off points (for connectors and units 16 to 63A) every 0.5m to 3m
  • Degree of protection IP55


- Canalis KDP: Flexible busbar trunking

  • Nominal current 20A
  • Tap-off points every 1.2m to 3m
  • Degree of protection IP55
 
 
 
 
 

Solution breakdown

Main products & systems:
  • Rigid busbar trunking for lighting distribution: Canalis KBA
  • Rigid busbar trunking 1 or 2 circuits for lighting distribution: Canalis KBB
  • Flexible busbar trunking for lighting distribution: Canalis KDP
  • Busbar trunking for low power distribution 160A: Canalis KN
  • Busbar trunking for medium power distribution 1000A: Canalis KS