-
CharacteristicsÂ
Main range Compactproduct name Compact NSXproduct or component type Circuit breakerdevice short name Compact NSX100Fdevice application Distributionpoles description 3Pprotected poles description 3tnetwork type ACnetwork frequency 50/60 Hz[In] rated current 100 A ( 40 °C )[Ui] rated insulation voltage 800 V AC 50/60 Hz[Uimp] rated impulse withstand voltage 8 kV[Ue] rated operational voltage 690 V AC 50/60 Hzbreaking capacity code F (36 kA) ACbreaking capacity 8 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-222 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-225 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-235 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-236 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-285 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-210 kA at 600 V AC 50/60 Hz conforming to UL 50825 kA at 480 V AC 50/60 Hz conforming to UL 50885 kA at 240 V AC 50/60 Hz conforming to UL 508[Ics] rated service breaking capacity Ics 11 kA 525 V AC 50/60 Hz conforming to IEC 60947-2Ics 35 kA 440 V AC 50/60 Hz conforming to IEC 60947-2Ics 36 kA 380/415 V AC 50/60 Hz conforming to IEC 60947-2Ics 4 kA 660/690 V AC 50/60 Hz conforming to IEC 60947-2Ics 85 kA 220/240 V AC 50/60 Hz conforming to IEC 60947-2Ics 12.5 kA 500 V AC 50/60 Hz conforming to IEC 60947-2suitability for isolation Yes conforming to EN 60947-2Yes conforming to IEC 60947-2utilisation category Category Atrip unit name TM-Dtrip unit technology Thermal-magnetictrip unit protection functions LItrip unit rating 25 A ( 40 °C )protection type Overload protection (thermal) LShort-circuit protection (magnetic) Ipollution degree 3 conforming to IEC 60664-1Complementary control type Togglemounting mode Fixedmounting support Backplateupside connection Frontdownside connection Frontauxiliary contact composition Withoutmechanical durability 50000 cycleselectrical durability 10000 cycles 690 V In conforming to IEC 60947-220000 cycles 690 V In/2 conforming to IEC 60947-230000 cycles 440 V In conforming to IEC 60947-250000 cycles 440 V In/2 conforming to IEC 60947-2connection pitch 35 mmlocal signalling Positive contact indicationlong time pick-up adjustment type Ir Adjustablelong time pick-up adjustment range 0.7...1 x Inlong time delay adjustment type Fixed[tr] long-time delay adjustment range 15 s 6 x Ir120...400 s 1.5 x Inshort-time pick-up adjustment type Isd Fixed[Isd] short-time pick-up adjustment range 300 Ashort-time delay adjustment type Fixedheight 161 mmwidth 105 mmdepth 86 mmproduct weight 2.05 kgEnvironment overvoltage category Class IIelectrical shock protection class Class IIstandards EN/IEC 60947UL 508product certifications CCCMarineEACIP degree of protection IP40 conforming to IEC 60529IK degree of protection IK07 conforming to IEC 62262ambient air temperature for operation -35...70 °Cambient air temperature for storage -55...85 °COffer Sustainability Sustainable offer status Green Premium productRoHS (date code: YYWW) REACh Product environmental profile AvailableProduct end of life instructions AvailableContractual warranty Warranty period 18 months 18 months -
Documents and Downloads
Language- English
CatalogueSizeAdd to My DocumentsCatalog Compact NSX & NSXm circuit breakers and switch-disconnectors from 16 to 630A - up to 690V (Version 1.7)Date 1/28/19Size 70.2 MBUser guideSizeAdd to My DocumentsCompact NSX100-630 - User guide (Version 00)Compact NSX - Use in explosive atmospheres (ATEX) (Version 04)CADSizeAdd to My Documents3P NSX100-250; Compact circuit breaker (Version 1.0)3P NSX100-250; Compact circuit breaker (Version 1.0)3P NSX100-250; Compact circuit breaker (Version 1.0)NSX100/160/250 3P; Compact circuit breakerCAD files for LV429636: NSX100/160/250 3P; Compact circuit breaker (Version 1.0)Instruction sheetSizeAdd to My DocumentsTM-D / TM-G / MA / NA / DC trip unit for breaker NSX100-250 A (Version 09)Circuit breaker/Switch-disconnector NSX100-250 A (Version 08)REACh DeclarationSizeAdd to My DocumentsEU RoHS DeclarationSizeAdd to My Documents -
Technical FAQs
No results found.Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.