-
ลักษณะ
Main range Compactproduct name Compact NSXproduct or component type Circuit breakerdevice short name Compact NSX250Bdevice application Distributionpoles description 4Pprotected poles description 3tneutral position Leftnetwork type ACnetwork frequency 50/60 Hz[In] rated current 250 A ( 40 °C )[Ui] rated insulation voltage 800 V AC 50/60 Hz[Uimp] rated impulse withstand voltage 8 kV[Ue] rated operational voltage 690 V AC 50/60 Hzbreaking capacity code B (25 kA) ACbreaking capacity 25 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-215 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-220 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-240 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2[Ics] rated service breaking capacity Ics 15 kA 500 V AC 50/60 Hz conforming to IEC 60947-2Ics 20 kA 440 V AC 50/60 Hz conforming to IEC 60947-2Ics 25 kA 380/415 V AC 50/60 Hz conforming to IEC 60947-2Ics 40 kA 220/240 V AC 50/60 Hz conforming to IEC 60947-2suitability for isolation Yes conforming to EN 60947-2Yes conforming to IEC 60947-2utilisation category Category Atrip unit name TM-Dtrip unit technology Thermal-magnetictrip unit protection functions LItrip unit rating 250 A ( 40 °C )protection type Overload protection (thermal) LShort-circuit protection (magnetic) Ipollution degree 3 conforming to IEC 60664-1Complementary control type Togglemounting mode Fixedmounting support Backplateupside connection Frontdownside connection Frontmechanical durability 20000 cycleselectrical durability 10000 cycles 440 V In conforming to IEC 60947-210000 cycles 690 V In/2 conforming to IEC 60947-220000 cycles 440 V In/2 conforming to IEC 60947-25000 cycles 690 V In conforming to IEC 60947-2connection pitch 35 mmlocal signalling Positive contact indicationneutral protection setting No protection 3tlong time pick-up adjustment type Ir Adjustablelong time pick-up adjustment range 0.7...1 x Inlong time delay adjustment type Fixed[tr] long-time delay adjustment range 15 s 6 x Ir120...400 s 1.5 x Inshort-time pick-up adjustment type Isd Adjustable[Isd] short-time pick-up adjustment range 5...10 x Inshort-time delay adjustment type Fixedheight 161 mmwidth 140 mmdepth 86 mmproduct weight 2.8 kgEnvironment overvoltage category Class IIelectrical shock protection class Class IIstandards EN/IEC 60947product certifications CCCMarineEACIP degree of protection IP40 conforming to IEC 60529IK degree of protection IK07 conforming to IEC 62262ambient air temperature for operation -35...70 °Cambient air temperature for storage -55...85 °COffer Sustainability Sustainable offer status Green Premium productRoHS (date code: YYWW) REACh Product environmental profile AvailableProduct end of life instructions AvailableContractual warranty Warranty period 18 months 18 months -
เอกสารและดาวน์โหลด
ภาษา- English
Catalogueขนาดเพิ่มในเอกสารของฉันCatalog Compact NSX & NSXm circuit breakers and switch-disconnectors from 16 to 630A - up to 690V (รุ่น 1.7)วันที่ 1/28/19ขนาด 70.2 MBUser guideขนาดเพิ่มในเอกสารของฉันCompact NSX100-630 - User guide (รุ่น 00)Compact NSX - Use in explosive atmospheres (ATEX) (รุ่น 04)CADขนาดเพิ่มในเอกสารของฉัน4P NSX100-250; Compact circuit breaker (รุ่น 1.0)4P NSX100-250; Compact circuit breaker (รุ่น 1.0)4P NSX100-250; Compact circuit breaker (รุ่น 1.0)NSX100/160/250 4P; Compact circuit breaker (รุ่น 1.0)Instruction sheetขนาดเพิ่มในเอกสารของฉันTM-D / TM-G / MA / NA / DC trip unit for breaker NSX100-250 A (รุ่น 09)Circuit breaker/Switch-disconnector NSX100-250 A (รุ่น 08) -
คำถามทางเทคนิคที่พบบ่อย
ไม่พบผลลัพธ์ขออภัย คำถามที่พบบ่อยที่เกี่ยวข้องไม่สามารถใช้งานได้เนื่องจากปัญหาทางเทคนิคชั่วคราว โปรดลองอีกครั้งในภายหลัง